Call Now Skip to main content

Work report — Austin & Central Texas

Perimeter Rot Repair: Eave Framing

What a sealed-over roof penetration cost, and what it took to put right.

PropertyKyle, TX — single-story, asphalt shingle
Job typeRepair — eave framing, decking and trim
Reported issueRotted fascia and soffit along the eave
Cause foundLeaking satellite dish mount, sealed over rather than removed
ScopeDish mount bases removed · eave opened to sound material · deck edge, sub-fascia and lookouts replaced · reframed flush · self-adhered membrane and eave metal · shingles tied back in · soffit and fascia replaced and painted · new intake vent · existing baffles and insulation reinstalled

What failed. A satellite dish had been mounted straight through the roof plane near the eave. When it leaked, somebody sealed over it with a spray-on rubber product instead of flashing it or taking it off. From the ground that looks like a repair. It is not one. Sealant fills a gap; it does not carry water anywhere. The lag bolts kept letting water in, it ran down the deck to the eave, and there it sat. Over time it took the deck edge, then the sub-fascia, then the lookouts — framing, not trim. By the time the fascia rotted through and became visible from the driveway, the structure behind it was already gone.

What we did. Removed the dish bases entirely and hauled them off. Opened the eave until we reached sound wood in both directions, replaced the compromised decking and framing, and reframed flush so the new trim had solid backing. Set self-adhered membrane and new eave metal in the repaired area, tied the shingles back in, and replaced the soffit and fascia. A new intake vent went in at the existing opening, and the existing baffles and insulation were put back as they were found.

The photographs below are in the order the work was done, beginning with the condition as we found it. Client name and address withheld.

The repair, in order

As found from the ground: fascia rotted through, board split, the damage finally visible.
01As found from the ground: fascia rotted through, board split, the damage finally visible.
The underside — cracked soffit and a run of old sealant, with rot behind the fascia edge.
02The underside — cracked soffit and a run of old sealant, with rot behind the fascia edge.
The cause: a satellite dish mount lag-bolted straight through the roof plane near the eave.
03The cause: a satellite dish mount lag-bolted straight through the roof plane near the eave.
Closer — the mount and its bases smeared over with a spray-on rubber sealant.
04Closer — the mount and its bases smeared over with a spray-on rubber sealant.
Lifting the shingle edge at the eave: the deck edge behind it was black and delaminated.
05Lifting the shingle edge at the eave: the deck edge behind it was black and delaminated.
Shingles opened where the deck underneath had gone soft.
06Shingles opened where the deck underneath had gone soft.
Opened up: deck and framing at the eave reduced to punk, insulation exposed.
07Opened up: deck and framing at the eave reduced to punk, insulation exposed.
A lookout cut back — rotted through its full section, not just at the surface.
08A lookout cut back — rotted through its full section, not just at the surface.
The eave opened further and the failed member removed, with new stock going in behind it.
09The eave opened further and the failed member removed, with new stock going in behind it.
Old rotted sub-fascia at left, new treated stock at right — opened until the wood was sound.
10Old rotted sub-fascia at left, new treated stock at right — opened until the wood was sound.
New framing set in, with the existing baffles and insulation put back as they were found.
11New framing set in, with the existing baffles and insulation put back as they were found.
Framing rebuilt and reframed flush, decking patched in, the intake vent opening kept clear.
12Framing rebuilt and reframed flush, decking patched in, the intake vent opening kept clear.
New decking fastened to the rebuilt framing, flush with the surrounding plane.
13New decking fastened to the rebuilt framing, flush with the surrounding plane.
Self-adhered membrane bonded across the repaired eave and lapped into the existing underlayment.
14Self-adhered membrane bonded across the repaired eave and lapped into the existing underlayment.
New eave metal over the membrane, with starter set on top of it.
15New eave metal over the membrane, with starter set on top of it.
Shingles woven back into the existing courses across the repaired run.
16Shingles woven back into the existing courses across the repaired run.
Soffit and fascia replaced and painted, with a new intake vent set in the existing opening.
17Soffit and fascia replaced and painted, with a new intake vent set in the existing opening.
The finished eave line.
18The finished eave line.

Recap

What was found, and what replaced it.

DetailCondition foundRebuilt as — and the reason
Roof penetrationSatellite dish mount lag-bolted through the plane near the eave, sealed over with a spray-on rubber product after it leaked.Bases removed and hauled off; the openings closed inside the rebuilt assembly. A penetration has to be flashed or eliminated — sealing over one only delays the discovery.
Deck edgeSaturated and delaminated at the eave; soft underfoot where water had been collecting.Cut back to sound material and replaced with new decking fastened to the rebuilt framing.
Sub-fascia & lookoutsRotted through the full section — structural framing, not just trim.Replaced and reframed flush, so the new fascia and soffit had solid wood to fasten to.
Eave waterproofingThe failed area had no sound assembly left to work with.Self-adhered membrane bonded across the repaired deck and lapped into the existing underlayment, with new eave metal and starter over it.
Soffit & intakeSoffit cracked and stained; intake vent, baffles and insulation in place.Soffit and fascia replaced and painted, with a new intake vent at the existing opening. Baffles and insulation put back as found — not the problem here.

What this job was actually about

A dish mount is a hole in a roof. So is a pipe, a vent or a solar standoff, and each needs metal that carries water around it and back onto the surface. When one leaks, the instinct is to seal it — and sealant will stop the drip for a season, which is exactly the problem. It hides the leak while the water keeps going somewhere. Here it went into the deck edge and the framing. The cost of this job was not caused by the dish. It was caused by sealing over the dish.

Scope note. This was a repair to a defined area of the eave. The rot was chased until sound material was reached in both directions and the framing rebuilt flush. Areas not opened were not inspected.

About this report. These photographs were taken during this project and show selected stages of the work. This report records what was done on this job and what was found. It is not an inspection certification, a condition report, or a warranty, and it does not add to or change the scope of any agreement. Scope, materials and methods on any project are set by that project’s signed estimate and contract. Conditions not opened were not inspected, and nothing here is a warranty or guarantee of future performance on any other property.

Schedule a Free Roof Inspection

Fascia that looks rotted from the driveway usually has a story behind it. We’ll find the source before we quote the fix. See our roof repair services.