Our Promise
We’ll Tell You When You Don’t Have a Claim
Not every storm means a new roof. Sometimes the honest answer is “your roof is fine” — and we’ll always tell you that.
A lot of roofing companies push insurance claims because a replacement is a payday. The problem: filing a claim that goes nowhere can put a mark on your record and even raise your rates — for damage that was never really there.
We screen for real, functional damage first. If it’s there, we’ll document it and stand behind it. If it’s not, we’ll say so. That’s the whole point: when we tell you that you do have a claim, you can believe it — because we’re the same people who’ll tell you when you don’t.
The Technical Side — For Inspectors & Adjusters
Claims are logged to shared industry databases (e.g., the C.L.U.E. report) whether or not they pay. A denied or withdrawn claim still follows the property. Pre-screening for functional damage protects the homeowner from an unnecessary claim and protects the carrier relationship.
Storm Damage
Does Small Hail Actually Damage a Roof?
Not always. Hail has to be big or hard enough to break the shingle’s protective surface. Small hail often just leaves cosmetic marks that don’t affect how the roof performs.
Think of the granules on a shingle as its sunscreen and armor. Functional damage is hail that fractures the shingle or knocks off enough granules to expose the asphalt underneath — that shortens the roof’s life. Cosmetic damage is a mark you can see that doesn’t change how the roof sheds water.
A hailstorm showing up on a radar report doesn’t automatically mean your roof was damaged. The size of the hail, how hard it fell, the wind, and how old your shingles are all matter.
The Technical Side — For Inspectors & Adjusters
Soft metals — vent caps, gutters, downspouts, and flashings — dent before shingles bruise, so they’re the reliable indicator surfaces. When the soft metals show minimal marking, functional mat bruising is unlikely. Assessment follows a functional-vs-cosmetic framework (e.g., HAAG methodology); there is no single “magic” hail size, but sub-1″ hail on a sound shingle rarely produces functional damage.
Storm Damage
What Hail Does to Soft Metals (the Inspector’s “Tell”)
Before we ever call hail damage on a roof, we read the metal. Vents, gutters, and flashing dent before shingles bruise — so they tell the real story.
Shingles are tricky: a mark can be a bruise that shortens the roof’s life, or it can be cosmetic and mean nothing. Soft metals don’t lie. Aluminum and thin steel — vent caps, gutters, downspouts, and flashings — only dent when hail was actually big and hard enough to matter. So the first thing we do is look there.
If the soft metals are clean or barely marked, it’s unlikely the shingles took functional damage in that same storm. If they’re freshly dented in a consistent size and pattern, that points to a real hail event worth documenting on the shingles too. It keeps us honest both ways — it stops us from calling damage that isn’t there, and from missing damage that is.
The Technical Side — For Inspectors & Adjusters
Soft metals are the accepted spatter/indicator surfaces in a functional-vs-cosmetic assessment (e.g., HAAG methodology). Fresh, directional denting on caps, gutter aprons, and counterflashing corroborates hail size and impact energy; absent or oxidized marking argues against recent functional impact. Chalk-testing a square and correlating mat bruising to metal-spatter density is standard practice — no single hail diameter guarantees damage, but soft-metal response is the reliable cross-check.
Storm & Insurance
Your Roof Insurance Claim — and What It Actually Costs You
RCV, ACV, recoverable depreciation, your deductible, and the one endorsement that can quietly change all of it.
Our goal isn’t to talk you into a claim — sometimes we’ll tell you that you don’t have one. It’s to make sure that if you do have real storm damage, you know exactly how the money works, and what comes out of your pocket, before anyone sets foot on your roof.
How your claim gets paid — the order money moves
An approved claim usually pays in two parts. Here’s the sequence, so nothing surprises you:
- Inspection & scope — we document everything and tell you honestly if you have a claim. Free.
- Agreement — the scope in writing, matched to what the adjuster approved. Usually no big deposit for insurance work.
- First insurance check (ACV) — actual cash value, minus your deductible. Funds the start.
- You pay your deductible — your share of the job, due toward the work.
- We build your roof — the full system, documented start to finish.
- Final invoice submitted to your insurer.
- Depreciation released — on a true RCV policy, the final check comes and the balance settles.
The technical side — for adjusters & inspectors
Initial payment is ACV (RCV less depreciation) net of deductible. Recoverable depreciation releases on an RCV policy upon completion and final invoice — unless a roof-surfaces settlement endorsement caps the loss by roof age. Scope reconciled to line items.
The “Roof Payment Schedule” endorsement — read your policy for this one
This is the fine print that surprises the most people. Some carriers (Allstate’s is the best-known) attach a Roof Payment Schedule — also called a Roof Surface Payment Schedule or Scheduled Roof Settlement. Instead of paying to replace your roof, it pays a set percentage based on the roof’s age. The older the roof, the less they pay — and you cover the difference.
100%new roof
~80%~5 years
~50%~10 years
~30%~15 years
Illustrative only — the real schedule varies by carrier, policy, and roof material. Always read your own endorsement.
The catch: this can sit inside an otherwise “replacement cost” (RCV) policy. You think you’re fully covered — until a claim, when it behaves like ACV and you pay the age-based gap. Most homeowners find out the hard way, after the storm. Look for “Roof Payment Schedule,” “Roof Surface(s) Payment Schedule,” or “Scheduled Roof Settlement” in your declarations — and we’ll help you read it straight.
What you’ll actually pay out of pocket
Your deductible is your guaranteed out-of-pocket — plan on it from day one. Whether that’s all you pay comes down to how your roof is covered:
True RCV, no roof endorsementYou recover the depreciation. Real cost ≈ just your deductible.
ACV policyDepreciation is never reimbursed. Deductible + that gap.
RCV + Roof Payment ScheduleLooks full, pays by age. Deductible + the age-based reduction.
So before you file: find out how your roof is actually covered — the policy type and any roof endorsement. It’s the biggest factor in what a new roof costs you.
Two things an honest roofer will always tell you
We can’t “eat” your deductible — and be wary of anyone who offers to. In Texas, waiving or absorbing a homeowner’s deductible is against the law (House Bill 2102). A contractor comfortable breaking that rule should make you wonder about the others.
We’re your roofer, not your public adjuster. We document everything and hand you and your adjuster clear, honest evidence — but negotiating your claim for you is a licensed role under Texas law that a contractor doing the work can’t fill.
How Your Roof Works
How Roofs Work
Roof Pitch and Underlayment: Why Low Slopes Need Extra
Flatter roofs shed water more slowly, so the building code requires an extra layer of waterproofing underneath the shingles.
On a steep roof, water runs off fast. On a low slope, it lingers — and can wick back under the shingles. To handle that, low slopes get a second layer of underlayment: the shingle’s backup raincoat.
If part of your roof is low-sloped, it’s worth knowing whether it was built with that double layer. You can’t see it without lifting shingles, but it makes a real difference in leak resistance.
The Technical Side — For Inspectors & Adjusters
Per IRC R905.2.2, asphalt shingles are permitted down to 2:12. On slopes from 2:12 up to (but not including) 4:12, two layers of underlayment are required; a single layer is permitted only at 4:12 and steeper. Below 2:12, shingles are not permitted — a low-slope membrane system is required.
Roof Details
High-Eave Flashing: What It Is (and Why It Gets “Flagged”)
Where a roof edge meets a wall that rises above it, flashing carries water out onto the roof below instead of letting it run behind the wall.
Picture a small metal ramp that keeps water on the outside of the wall. At a “high eave,” the shingle is intentionally not run over the drip edge — the flashing does that job instead.
Because of that, an inspector who isn’t familiar with the detail may “flag” it as if shingle coverage is missing. But if the flashing is there, it’s working exactly as designed. If a report flags “high-eave flashing,” the right question is simply: is the flashing present?
The Technical Side — For Inspectors & Adjusters
At a headwall/high-eave condition, the counterflashing or apron directs discharge onto the lower field. Shingle terminating short of the drip edge at that location is correct detailing, not a deficiency — provided the metal is installed and lapped properly.
Ventilation
Attic Ventilation: The 1-in-300 Rule, in Plain English
Your attic needs to breathe — cool air in low at the eaves, hot air out high near the ridge. Get the balance wrong and you cook the roof from the inside.
A roof is a system, not just shingles. Cool air comes in through intake vents at the soffits (the underside of your eaves) and pushes hot, damp air out through exhaust vents up high. When that airflow is balanced, the attic stays closer to outdoor temperature, the shingles run cooler, and moisture doesn’t sit up there rotting the deck.
The rule of thumb is one square foot of vent opening for every 300 square feet of attic floor — split about half intake, half exhaust. Too little venting, or all exhaust and no intake, gives you a hot attic that ages shingles early and can grow mold on the decking. It’s one of the most common things done wrong, and one of the cheapest to get right.
The Technical Side — For Inspectors & Adjusters
IRC R806.2 sets minimum net free ventilating area at 1/150 of the vented space, reduced to 1/300 where a balanced system places 40–50% of the venting in the upper portion (at least 3 ft above the eave) with the balance as low intake — or where a Class I/II vapor retarder is used. Net free area (NFA), not vent count, is what’s measured, and intake must at least equal exhaust or the exhaust pulls make-up air from itself instead of the soffits.